6216/C4VL0241 Electrically Insulated Ball Bearings

6216/C4VL0241 Electrically Insulated Ball Bearings

The picture shows the TFL 6216-C4VL0241 bearing.

Buy 6216/C4VL0241 Electrically Insulated Bearings Online – Low MOQ & Factory Prices

$ 1620 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6216/C4VL0241
  • Equivalent Interchange 6216/C4VL0241 (SKF), 6216-J20AA-C4 (FAG), 6216-M-C4-SQ77 (NKE), 6216HDY2C3 (NSK), 7MC3-6216C3 (NTN)
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL0241
  • Insulating Coating Types Insulation coating on outer ring
  • Manufacturers TFL
  • Bore Diameter 80.0 mm
  • Outside Diameter 140.0 mm
  • Width 26.0 mm
  • Net Weight 1.43 kg
  • Basic Dynamic Load Rating 72.8 kN
  • Basic Static Load Rating 55.0 kN
  • Reference Speed 9500.0 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Sheet metal
  • Radial Internal Clearance C4
  • ROHS Compliant
  • REACH Compliant

6216/C4VL0241 Equivalent Interchange Brands

TFL’s 6216/C4VL0241 serves as a perfect equivalent to brands like SKF, NTN, FAG, NKE, and NSK insulated bearings. Not only does it match or exceed their quality in preventing electrical erosion, but it also offers superior advantages such as significantly lower prices, more flexible minimum order quantities (MOQ), faster global logistics delivery, and customizable options to meet specific application requirements.
TFL SKF FAG NKE NSK NTN
6216/C4VL0241
6216/C4VL0241
6216-J20AA-C4
6216-M-C4-SQ77
6216HDY2C3
7MC3-6216C3

Why Choose TFL 6216/C4VL0241 Electrically Insulated Bearings?

While major brands offer quality, TFL provides a smart alternative for B2B buyers. Our products match the ISO dimensions and electrical specs but come with lower pricing, flexible Low MOQs (no need to buy bulk cases), and faster logistics from our ready-to-ship inventory. We also offer customization for grease and seals that big brands often refuse for small orders.
The picture shows the TFL 6216/C4VL0241 bearing.

Features of 6216/C4VL0241

Common Applications of Electrically Insulated Bearings

The 6216/C4VL0241 is an insulated deep groove ball bearing designed to prevent electrical erosion caused by current passing through the bearing in industrial equipment. Its aluminum oxide coating provides electrical insulation up to 3000 V DC. It is suitable for high-power machinery such as electric motors, pumps, and generators, particularly in environments using Variable Frequency Drives (VFDs), effectively preventing lubricant degradation and surface damage caused by bearing currents.
The picture shows the TFL bearings, especially the Electrically Insulated Ball Bearings used in the motor.

VFD Industrial Motors

The 6216/C4VL0241 is commonly used for locating at the Non-Drive End (NDE) of low-voltage variable frequency drive (VFD) motors with power ratings around 45kW to 90kW, where the insulating coating cuts off the shaft current loop. In Siemens motors with Frame Size 225, the standard configuration or option for the Non-Drive End (NDE) often includes a 6216 bearing. When this motor is marked for “converter operation,” Siemens technical manuals recommend replacing the bearing at the NDE with an insulated bearing.
The picture shows the bearings of TFL, which are the electrically insulated ball bearings used in the pump.

Industrial Pumps

The 6216 is commonly used at the upper end or tail end (non-drive end) of vertical or horizontal motors driving large centrifugal pumps. Grundfos NKE 100-250 or similar single-stage end-suction pumps are typically equipped with 55kW-75kW motors (such as those manufactured by Siemens or WEG). When driven by a VFD cabinet, maintenance manuals recommend replacing the motor's tail-end bearing with a 6216/C4VL0241 to extend service life.

The picture shows the bearings of TFL and the Electrically Insulated Ball Bearings used by Wind Energy.

Wind Energy

Wind turbine nacelles are filled with high-frequency interference. The 6216/C4VL0241, a high-clearance insulated bearing, is commonly used at the Non-Drive End of Doubly Fed Induction Generators (DFIG) (for smaller turbines) or inside the Yaw Motors of large turbines. Vestas V80 series turbines are equipped with independent forced cooling systems. The cooling fan motors operate in environments with large temperature differences (requiring C4 clearance). The 6216 is a common model for such medium-sized auxiliary motors.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Does the insulation coating affect the C4 clearance dimensions?

No. The TFL manufacturing process accounts for the coating thickness. The final dimensions (140mm OD) and the internal C4 radial clearance are strictly within ISO tolerances after the coating is applied. It fits standard housings perfectly.

Is this bearing suitable for horizontal and vertical mounting?

Yes, the 6216/C4VL0241 is a deep groove ball bearing suitable for both mounting orientations. However, for vertical mounting in large motors, ensure the axial load does not exceed the bearing's capacity, or consider our paired installation options.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

Max. file size: 50 MB.
This field is for validation purposes and should be left unchanged.