VL0241 Outer-Ring Insulation – The 500 µm coating helps interrupt the current path through the bearing at the housing interface, reducing the risk of electrical pitting and fluting in inverter-driven motors.
450 kN Basic Dynamic Load Rating – The single-row NU design combines a machined brass cage and C3 radial internal clearance in a 100 × 215 × 47 mm envelope.
Low MOQ Available – Request a small quantity for a single motor overhaul or a volume quote for a scheduled maintenance program.
Cross-Reference Support – Send your original SKF, FAG or NKE designation. TFL can help you compare the mounting dimensions, clearance class and insulation requirements before ordering.
TFL NU 320 ECM/C3VL0241 is a replacement option for motor overhauls that specify a 100 × 215 × 47 mm single-row cylindrical roller bearing with outer-ring insulation. Use the full SKF, FAG or NKE designation below to check the bearing against the original motor specification. Pay particular attention to radial internal clearance. The listed FAG reference is C4, while the TFL bearing is C3. Confirm the required clearance and insulation rating before ordering.
| SKF | FAG | NKE |
|---|---|---|
| NU 320 ECM/C3VL0241 | NU320-E-M1-F1-J20AA-C4 | NU320-E-M6-C3-SQ77 |
TFL manufactures electrically insulated bearings and supports trial orders, maintenance purchases and distributor quantities. For an NU 320 replacement, send the original bearing designation or drawing with your required insulation rating. Our team can review the fit and provide a quote for the specified configuration.
100 × 215 × 47 mm mounting envelope – The 215 mm outside diameter and 47 mm width identify the NU 320 housing fit. Check both dimensions when sourcing a bearing for a 100 mm shaft.
Non-locating NU design – The bearing carries radial load and allows axial movement within the bearing in both directions, accommodating shaft expansion as the motor warms up.
C3 clearance with a machined brass cage – Check the shaft and housing fits and expected operating temperatures when selecting the initial clearance for the rebuild.
The TFL NU 320 ECM/C3VL0241 fits a 100 × 215 × 47 mm bearing seat. Its single-row cylindrical rollers support radial loads, its non-locating NU design accommodates shaft expansion, and its VL0241 outer-ring coating helps interrupt bearing current at the housing interface. Each feature addresses a different requirement in industrial motor service.
Belt tension pulls sideways on the motor pulley, creating a radial load at the drive-end bearing. Where the fan motor specifies an NU 320 at the non-locating position, the cylindrical rollers carry that radial load while allowing the shaft to expand axially during operation. The bearing’s 450 kN basic dynamic load rating is an input to the bearing life calculation. Use the actual belt tension, pulley overhang and operating speed to assess the fan duty.
During long operating runs, the pump motor shaft can grow axially as it heats up. In a locating/non-locating arrangement, the locating bearing sets the shaft’s axial position, while the NU 320 lets the inner ring move axially relative to the roller assembly. This accommodates thermal growth within the bearing while it continues to support radial load. For a rebuild, verify the available axial travel and check that the C3 radial clearance suits the shaft fit and operating temperature.
When shaft current discharges through a motor bearing, repeated arcing can pit the raceways and eventually produce fluting. The NU 320’s 500 µm ceramic coating on the outer ring adds an insulating barrier between the bearing and the motor housing. Where the motor’s electrical design calls for insulation at that interface, this configuration helps reduce discharge through the bearing while retaining the existing NU 320 mounting dimensions. Confirm the required DC breakdown voltage and check the motor grounding as part of the rebuild.
*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.
Discover more related products for your needs. Check out our hot-selling bearing models that serve as trusted alternatives to major brands like SKF and FAG—offering the same performance with greater value.