NU 320 ECM/C3VL0241 Electrically Insulated Cylindrical Roller Bearings

NU 320 ECM/C3VL0241 Electrically Insulated Cylindrical Roller Bearings

Heavy-Duty C3 NU 320 ECM/C3VL0241 – For 100 mm Industrial Motor Shaft Rebuilds

$ 359 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model NU 320 ECM/C3VL0241
  • Equivalent Interchange NU 320 ECM/C3VL0241 (SKF); NU320-E-M1-F1-J20AA-C4 (FAG); NU320-E-M6-C3-SQ77 (NKE);
  • Product Category Electrically Insulated Single Row Cylindrical Roller Bearings
  • Insulating Coating Types Insulation coating on outer ring
  • Coating Suffix VL0241
  • Manufacturers TFL
  • Bore Diameter 100.0 mm
  • Outside Diameter 215.0 mm
  • Width 47.0 mm
  • Net Weight 8.7 kg
  • Basic Dynamic Load Rating 391.0 kN
  • Basic Static Load Rating 440.0 kN
  • Reference Speed 3000.0r/min
  • Breakdown Voltage (DC) 3000 VDC
  • Layer Thic kNess 100 µm
  • Electrical Resistance Min. 200MΩ
  • Cage Material Machined brass
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

NU 320 ECM/C3VL0241 Equivalent Interchange Brands

TFL NU 320 ECM/C3VL0241 is a replacement option for motor overhauls that specify a 100 × 215 × 47 mm single-row cylindrical roller bearing with outer-ring insulation. Use the full SKF, FAG or NKE designation below to check the bearing against the original motor specification. Pay particular attention to radial internal clearance. The listed FAG reference is C4, while the TFL bearing is C3. Confirm the required clearance and insulation rating before ordering.

SKF FAG NKE
NU 320 ECM/C3VL0241 NU320-E-M1-F1-J20AA-C4 NU320-E-M6-C3-SQ77

Why Choose TFL?

TFL manufactures electrically insulated bearings and supports trial orders, maintenance purchases and distributor quantities. For an NU 320 replacement, send the original bearing designation or drawing with your required insulation rating. Our team can review the fit and provide a quote for the specified configuration.

Two TFL NU 320 ECM/C3VL0241 cylindrical roller bearings showing white insulated outer rings and brass cages.

Features of NU 320 ECM/C3VL0241

Common Applications of Electrically Insulated Bearings

The TFL NU 320 ECM/C3VL0241 fits a 100 × 215 × 47 mm bearing seat. Its single-row cylindrical rollers support radial loads, its non-locating NU design accommodates shaft expansion, and its VL0241 outer-ring coating helps interrupt bearing current at the housing interface. Each feature addresses a different requirement in industrial motor service.

TFL insulated roller bearings shown beside a blue industrial axial fan with a yellow safety grille.

Belt-Driven Industrial Fan Motors

Belt tension pulls sideways on the motor pulley, creating a radial load at the drive-end bearing. Where the fan motor specifies an NU 320 at the non-locating position, the cylindrical rollers carry that radial load while allowing the shaft to expand axially during operation. The bearing’s 450 kN basic dynamic load rating is an input to the bearing life calculation. Use the actual belt tension, pulley overhang and operating speed to assess the fan duty.

Industrial pump system with insulated cylindrical roller bearings

Continuous-Duty Process Pump Motors

During long operating runs, the pump motor shaft can grow axially as it heats up. In a locating/non-locating arrangement, the locating bearing sets the shaft’s axial position, while the NU 320 lets the inner ring move axially relative to the roller assembly. This accommodates thermal growth within the bearing while it continues to support radial load. For a rebuild, verify the available axial travel and check that the C3 radial clearance suits the shaft fit and operating temperature.

Industrial electric motors with insulated cylindrical roller bearings

VFD Motor Rebuilds After Electrical Fluting

When shaft current discharges through a motor bearing, repeated arcing can pit the raceways and eventually produce fluting. The NU 320’s 500 µm ceramic coating on the outer ring adds an insulating barrier between the bearing and the motor housing. Where the motor’s electrical design calls for insulation at that interface, this configuration helps reduce discharge through the bearing while retaining the existing NU 320 mounting dimensions. Confirm the required DC breakdown voltage and check the motor grounding as part of the rebuild.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Can NU 220 ECM/C3VL0241 fit the same housing?

Both models have a 100 mm bore. The NU 220 measures 180 mm outside diameter × 34 mm wide, while the NU 320 measures 215 mm × 47 mm. Use the housing bore and bearing seat width to identify the correct series.

Can I use 3,200 r/min as the maximum operating speed?

The table lists 3,200 r/min as the reference speed. To assess the intended operating speed, provide the actual radial load, lubricant, operating temperature and mounting fits.

How do I specify a 3,000 V DC breakdown requirement when requesting a quote?

Include 3,000 V DC breakdown voltage in your RFQ along with the full model number and order quantity. This model’s published range is 1,000–3,000 V DC. Ask TFL to confirm the configuration and available dielectric test documentation for the requested rating.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.