NU 324 ECM/C3VL0241 Electrically Insulated Cylindrical Roller Bearings

NU 324 ECM/C3VL0241 Electrically Insulated Cylindrical Roller Bearings

NU 324 ECM/C3VL0241 — Electrical Insulation for Motor Bearing Replacement

$ 493 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model NU 324 ECM/C3VL0241
  • Equivalent Interchange NU 324 ECM/C3VL0241 (SKF); NU324-E-XL-M1-J20AA-C3 (FAG); NU324-E-M6-C3-SQ77 (NKE); 7MC3-NU324EGRBC3 (NTN);
  • Product Category Electrically Insulated Single Row Cylindrical Roller Bearings
  • Insulating Coating Types Insulation coating on outer ring
  • Coating Suffix VL0241
  • Manufacturers TFL
  • Bore Diameter 120.0 mm
  • Outside Diameter 260.0 mm
  • Width 55.0 mm
  • Net Weight 15.0 kg
  • Basic Dynamic Load Rating 539.0 kN
  • Basic Static Load Rating 620.0 kN
  • Reference Speed 2400.0r/min
  • Breakdown Voltage (DC) 3000 VDC
  • Layer Thic kNess 100 µm
  • Electrical Resistance Min. 200MΩ
  • Cage Material Machined brass
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

NU 324 ECM/C3VL0241 Cross-Reference and Replacement Support

TFL supplies an own-brand alternative for purchases referencing SKF NU 324 ECM/C3VL0241. Its specification combines outer ring insulation, a machined brass cage and C3 radial internal clearance.

Related FAG, NTN and NKE references can help identify replacement options. Matching dimensions and insulation location provide a starting point; cage construction, load ratings, speed and electrical test requirements complete the comparison. TFL can quote against your existing part number or approved specification.

SKF FAG NKE NTN
NU 324 ECM/C3VL0241 NU324-E-XL-M1-J20AA-C3 NU324-E-M6-C3-SQ77 7MC3-NU324EGRBC3

Purchase NU 324 ECM/C3VL0241 to Your Replacement Specification

When an existing motor specifies an outer-ring-insulated NU 324 bearing, purchasing a standard uncoated version leaves out an essential part of the specification. TFL quotations identify the insulation position, clearance and cage configuration so your team can compare the proposed replacement clearly.

For distributor and maintenance orders, this model can be sourced alongside other bearing sizes. Neutral or private-label packaging requirements can be discussed, with price, availability and documentation confirmed for the requested quantity.

NU 324 ECM/C3VL0241 outer-ring-insulated cylindrical roller bearing

Features of NU 324 ECM/C3VL0241

Motor and Generator Applications for NU 324 ECM/C3VL0241

NU 324 ECM/C3VL0241 combines an insulated outer ring, a machined brass cage and C3 radial internal clearance. Its flangeless inner ring allows axial movement in both directions, making it suitable for non-locating positions in industrial motors and generators where radial loads, shaft thermal expansion and bearing currents are key considerations.

Industrial pump system with insulated cylindrical roller bearings

Variable-Speed Pump Motors

In converter-fed pump motors, bearing currents can pit rolling surfaces and contribute to premature repair. NU 324 ECM/C3VL0241 places an insulating barrier between the outer ring and motor housing. At the non-locating position, its NU construction also allows shaft expansion as the motor warms up.

Industrial electric motors with insulated cylindrical roller bearings

Industrial Motor Rebuilds

During a motor rebuild, replacing an insulated bearing with an ordinary NU 324 can restore an unwanted conductive path through the housing. This configuration retains outer ring insulation alongside radial roller support. C3 clearance provides allowance for the reduction in internal clearance caused by interference fits and operating temperature differences.

Industrial generator with insulated cylindrical roller bearings

Generator Rotor Supports

Generator rotor supports may need to carry radial loads without restraining thermal shaft expansion. This bearing provides axial freedom within the NU arrangement, while its coated outer ring helps interrupt the bearing-to-housing current path. It suits positions where the generator design specifies this size and insulation location.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Does the outer ring coating increase the bearing’s outside diameter?

The finished bearing retains the nominal 120 × 260 × 55 mm boundary dimensions. The coating is incorporated into the finished specification rather than added as an extra allowance to the 260 mm outside diameter. Housing fit and mounting requirements are checked against the supplied bearing drawing.

Can an ordinary NU 324 ECM/C3 replace the VL0241 version?

It may share the same nominal dimensions, but it does not provide the specified outer ring insulation. Where that insulation forms part of the motor’s bearing-current protection, an uncoated replacement changes the electrical arrangement. Keeping the complete designation in the order helps avoid this substitution.

Can TFL quote against a FAG, NTN or NKE part number?

Yes. TFL can review the complete reference and propose a corresponding TFL configuration. For this size, the comparison includes the NU arrangement, outer ring insulation, brass cage and C3 clearance. Different brands may use different cage designs, load ratings and insulation specifications, so the quotation identifies the offered configuration.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.