Product Parameters

  • Model 6228/C3VL0241
  • Equivalent Interchange 6228/C3VL0241 (SKF); 6228-J20AA-C3 (FAG); 7MC3-6228C3 (NTN);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL0241
  • Insulating Coating Types Insulation coating on outer ring
  • Manufacturers TFL
  • Bore Diameter 140.0 mm
  • Outside Diameter 250.0 mm
  • Width 42.0 mm
  • Net Weight 7.64kg
  • Basic Dynamic Load Rating 174.0 kN
  • Basic Static Load Rating 150.0 kN
  • Reference Speed 5300.0 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Sheet metal
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6228/C3VL0241 Equivalent Interchange Brands

TFL 6228/C3VL0241 is a 100% equivalent and direct replacement for large-size insulated bearings from SKF and FAG in terms of dimensional specifications, standard pressed steel cage structure, C3 clearance, and VL0241 parameters. Customers do not need to perform any secondary machining on existing motor shafts or housings during large motor or industrial pump overhauls.

SKF FAG NTN
6228/C3VL0241 6228-J20AA-C3 7MC3-6228C3

Why Choose TFL?

Supplying large-bore insulated bearings with a 140mm bore poses strict demands on supply chain integration and precision tolerances. Relying on a robust premium industrial transmission supply chain network and an ISO 9001 certified quality control system, TFL seamlessly integrates imported plasma ceramic spraying processes with precision large-bearing standards. We provide high-reliability anti-erosion solutions rivaling top global brands, backed by a professional engineering team for technical selection and diagnostic support. With rapid-response stock availability and No MOQ, TFL is dedicated to helping global clients eliminate lead-time risks on large specialized parts, achieving significant cost optimization.

insulated bearing 6228/C3VL0241, coated deep groove ball bearing for current

6228/C3VL0241

Common Applications of Electrically Insulated Bearings

TFL 6228/C3VL0241 is widely applied in large VFD drive equipment operating under standard, smooth industrial loads. Typical applications encompass large horizontal water transport pumps in municipal or industrial water systems, large centrifugal fans in chemical plants, drive shafts in paper mills, and centrifugal compressors in large commercial HVAC systems. Its standard steel cage structure is ideal for steady-state continuous high-speed operation, while the reliable outer-ring insulation perfectly cuts off high-frequency shaft voltages introduced by VFD systems within standard housing seats.

Large industrial electric motor connected to a variable frequency drive system in a factory setting.

General Large VFD Motors

In general high-power industrial VFD motors like the Siemens 1LE1 or ABB M3BP series, high-frequency PWM signal interference often causes rotor shaft currents to break down the lubricating oil film. TFL 6228/C3VL0241’s steel cage design is lightweight and low-friction, perfectly suited for medium-high speed continuous and smooth operation. Its outer-ring 3000V alumina insulation provides excellent anti-erosion protection, making it a highly cost-effective SKF INSOCOAT alternative for MRO in such large motors.

Photo showing insulated bearing in a water pump mechanism

Large Industrial Water Pumps

In large VFD horizontal centrifugal pumps by Flowserve and Grundfos widely used in municipal water supply and power plant cooling systems, equipment often requires uninterrupted operation for months. Utilizing TFL 6228/C3VL0241 as a critical support bearing, its C3 clearance fully adapts to the temperature rise of the 140mm large bearing during full-speed runs, while effectively cutting off electrical erosion leakage caused by inverter harmonics, drastically extending the time interval between pump overhauls.

the picture shows a big commercial hvac and two insulated bearings beside.

Large Centrifugal Compressors & HVAC

At the main drive ends of centrifugal compressors by Atlas Copco or Trane in large chemical plants or commercial buildings, high-speed rotation and high-power VFDs easily trigger intense common-mode shaft voltages. TFL 6228/C3VL0241 provides stable support with its 140mm bore and 50–200 MΩ insulation resistance, efficiently isolating high-frequency interference currents. This ensures the compressor raceways are safe from arc flaking threats, improving the overall uptime of the energy production line.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Why do many plants prefer using the TFL 6228/C3VL0241 insulated bearing to replace the "grounding carbon brushes (or grounding rings)" originally installed on the motor shaft?

Because shaft grounding carbon brushes (or grounding rings) present unavoidable mechanical wear and maintenance hazards. Carbon brushes wear heavily under long-term high-speed rotation, producing conductive carbon dust that can easily deposit on the shaft end and contaminate the windings. Furthermore, once contaminated with grease or dust during operation, the contact resistance of the carbon brush spikes, rendering the grounding path ineffective. Carbon brushes typically require periodic replacement and cleaning every few months. Conversely, the TFL 6228/C3VL0241 electrically insulated bearing is a "maintenance-free" solution with zero mechanical friction wear, zero carbon dust generation, and consistent high-isolation protection throughout the bearing's entire service life, drastically lowering maintenance labor and downtime costs for plant MRO.

When operating in high-altitude extreme environments such as northwestern mining areas or wind farms, will the high-voltage insulation blocking capability of the TFL 6228/C3VL0241 decrease?

Absolutely not. According to Paschen's Law in electrical physics, the breakdown voltage of air drops significantly with decreasing atmospheric pressure (increasing altitude), which is why "air-gap discharge" in motors is highly prone to occur in high-altitude areas. However, the TFL 6228/C3VL0241 relies on a dense solid alumina (Al2O3) dielectric for insulation blocking. The breakdown voltage and dielectric constant of a solid medium are completely unaffected by changes in ambient atmospheric pressure and altitude. Therefore, even when operating in low-pressure environments above 3000 meters in altitude, its high-grade 3000V electrical isolation protection remains 100% stable, making it ideal for high-plateau and high-mining environments.

Modern IGBT inverters generate very sharp dv/dt high-frequency discharge pulses. Can this coating really block such high-frequency electrical shocks?

Yes, absolutely. In addition to high DC insulation resistance exceeding 50 MΩ, the outer-ring coating thickness (100-500μm) of TFL 6228/C3VL0241 is precisely controlled to provide excellent "low parasitic capacitance" properties. When facing sharp high-frequency dv/dt transient voltages (PWM pulses) from VFDs, the coating acts as an extremely high-impedance AC barrier, drastically reducing the passage rate of high-frequency common-mode currents to guarantee stable discharge isolation even when facing transient peak voltages up to 3000V.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.