6036M/C3VL0241 Electrically Insulated Ball Bearings

6036M/C3VL0241 Electrically Insulated Ball Bearings

Heavy-Duty & Reinforced 6036M/C3VL0241 - MRO Replacement

$ 493 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6036M/C3VL0241
  • Equivalent Interchange 6036M/C3VL0241 (SKF); 6036-M-J20AA-C3 (FAG);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL0241
  • Insulating Coating Types Insulation coating on outer ring
  • Manufacturers TFL
  • Bore Diameter 180.0 mm
  • Outside Diameter 280.0 mm
  • Width 46.0 mm
  • Net Weight 10.6 kg
  • Basic Dynamic Load Rating 201.0 kN
  • Basic Static Load Rating 199.0 kN
  • Reference Speed 4050 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6036M/C3VL0241 Equivalent Interchange Brands

TFL 6036M/C3VL0241 has an interchange basis with corresponding SKF and FAG electrically insulated bearings through its 180 × 280 × 46 mm dimensions, C3 clearance, and outer-ring insulation structure. Unlike VL2071 inner-ring insulation, VL0241 places the insulation coating on the outer ring, so replacement should not be determined only from the same base designation. Buyers should verify the complete suffix, insulation location, clearance, cage, mounting fits, and operating conditions. TFL can assist with SKF/FAG interchange list and direct replacement review based on the original bearing designation, photos, and equipment information.

SKF FAG
6036M/C3VL0241 6036-M-J20AA-C3

Why Choose TFL?

TFL supports industrial buyers, motor repair teams, and distributors with insulated bearing model verification, interchange confirmation, and pre-shipment inspection. For large outer-ring insulated bearings such as 6036M/C3VL0241, we focus on the 180 × 280 × 46 mm dimensions, C3 clearance, VL0241 insulation location, cage, and complete original brand suffix. TFL supports No MOQ, small maintenance orders, volume purchasing, OEM/ODM, and consolidated shipments, helping customers control purchasing costs and inventory pressure when replacing SKF, FAG, and other branded bearings. The listed ROHS and REACH status is Compliant; specific document requirements can be confirmed at the RFQ or order stage.

Features of 6036M/C3VL0241

Common Applications of Electrically Insulated Bearings

TFL 6036M/C3VL0241 electrically insulated deep groove ball bearing is mainly suitable for large inverter motors, industrial motors, generators, pump motors, fan motors, and heavy-duty drive systems. Its VL0241 outer-ring insulation helps interrupt current paths between the housing and bearing outer ring, reducing electrical erosion and raceway damage risk under inverter-driven operation. The 180 × 280 × 46 mm dimensions, C3 clearance, and outer-ring insulation structure suit continuous-duty conditions in large equipment. Final selection should confirm the required insulation location and verify dimensions, clearance, fits, load, speed, and temperature rise against the original bearing.

The picture shows the Electrically Insulated Bearings used in modern motors.

Large Inverter Motors

TFL electrically insulated deep groove ball bearings such as 6036M/C3VL0241 can be considered for large inverter motor equipment types, including Siemens 1LE0001 and ABB M3BP series. Inverter-driven operation can generate high-frequency voltage and shaft current, allowing the bearing to become part of the current path and increasing the risk of electrical erosion. With VL0241 outer-ring alumina ceramic insulation, 6036M/C3VL0241 can be considered as an alternative to comparable SKF or FAG insulated bearings where outer-side insulation is required. This is an application-type reference, not an installed case.

Large industrial electric motor connected to a variable frequency drive system in a factory setting.

Large Industrial Motors

TFL 6036M/C3VL0241 can be considered for bearing positions in large industrial motors, particularly equipment operating continuously where shaft current protection and outer-ring insulation are required. Large industrial motors operating with inverter drives or other electrical conditions may experience shaft voltage and circulating current, which can lead to electrical erosion, fluting, and lubricant degradation when current passes through the bearing. With VL0241 outer-ring alumina ceramic insulation, C3 clearance, and a brass cage, 6036M/C3VL0241 can be considered as an alternative to comparable SKF or FAG electrically insulated bearings. This is an application-type reference, not an installed case.

The picture shows the insulated bearings used on wind turbines.

Wind Turbine Generators

TFL electrically insulated bearings such as 6036M/C3VL0241 can be considered for generator bearing positions in wind turbines, including equipment types from Vestas, Goldwind, and Siemens Gamesa. Wind turbine generators operate under variable speed, vibration, humidity, and fluctuating load conditions, making shaft-current protection an important consideration for generator bearing selection. The VL0241 outer-ring insulation of 6036M/C3VL0241 can be considered for wind turbine generator bearing replacement review, but the original equipment must first be confirmed to require outer-ring rather than VL2071 inner-ring insulation. This is an application-type reference, not an installed case.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Does 6036M/C3VL0241 have inner-ring or outer-ring insulation?

6036M/C3VL0241 uses VL0241 outer-ring insulation, with the insulation coating applied to the bearing outer ring. The main difference from VL2071 inner-ring insulated bearings is the insulation location. Replacement should therefore confirm the required insulation position rather than comparing only the 180 × 280 × 46 mm basic dimensions.

What type of motors can use 6036M/C3VL0241?

It can be considered as an electrically insulated bearing candidate for large inverter motors and large industrial motors, particularly where shaft current is a concern and the original equipment requires outer-ring insulation. Final selection should also verify the original bearing dimensions, C3 clearance, load, speed, and insulation location.

Can 6036M/C3VL0241 be used as a replacement for SKF or FAG insulated bearings?

It can be reviewed as a replacement, but the base designation 6036M alone is not sufficient for confirmation. Buyers should check the complete SKF/FAG designation, C3 clearance, outer-ring insulation location, cage, and equipment mounting conditions. For large motor or generator maintenance orders, providing the original bearing designation and photos can help confirm the replacement option more efficiently.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.