Product Parameters

  • Model 6336M/C4VL2071
  • Equivalent Interchange 6336M/C4VL2071 (SKF); 6336-M-J20C-C4 (FAG);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL2071
  • Insulating Coating Types Inner ring insulation coating
  • Manufacturers TFL
  • Bore Diameter 180.0 mm
  • Outside Diameter 380.0 mm
  • Width 75.0 mm
  • Net Weight 43 kg
  • Basic Dynamic Load Rating 355.0 kN
  • Basic Static Load Rating 405.0 kN
  • Reference Speed 3000 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C4
  • ROHS Compliant
  • REACH Compliant

6336M/C4VL2071 Equivalent Interchange Brands

TFL 6336M/C4VL2071 has an interchange basis with SKF, FAG, and other insulated bearing types through its dimensions, C4 clearance, and VL2071 inner-ring insulation structure. VL2071 indicates an inner-ring insulation design for large motor and generator applications requiring shaft-side current isolation.

Compared with C3 clearance versions, C4 clearance is mainly selected for higher operating temperatures, greater thermal expansion, or applications requiring increased internal clearance. Replacement should verify the complete designation, insulation location, clearance class, and operating conditions.

SKF FAG
6336M/C4VL2071 6336-M-J20C-C4

Why Choose TFL?

TFL focuses on electrically insulated bearing supply, providing model verification, interchange review, and delivery support for industrial buyers, motor repair teams, and distributors. For large VL2071 inner-ring insulated bearings such as 6336M/C4VL2071, we verify dimensions, C4 clearance, insulation location, cage type, and complete original designations to reduce selection errors.

TFL supports No MOQ, small maintenance orders, bulk purchasing, OEM/ODM, and consolidated shipments, helping customers meet high-temperature operation and electrical insulation requirements while reducing sourcing costs.

inner ring insualted ball bearing 6336M/C4VL2071 with brass cage

Features of 6336M/C4VL2071

Common Applications of Electrically Insulated Bearings

TFL 6336M/C4VL2071 electrically insulated deep groove ball bearing is suitable for large inverter motors, industrial generators, high-temperature continuous-duty electric drive systems, and other equipment where shaft current protection is required.

The VL2071 inner-ring insulation structure helps isolate shaft-side current paths and reduce electrical erosion risks. C4 clearance is suitable for large equipment with higher operating temperatures, greater thermal expansion, or increased internal clearance requirements.

Final selection should be verified by original dimensions, insulation location, clearance, fits, load, and speed.

Massive electric drive motor for a mine hoist system requiring heavy-duty insulated 6238M bearings.

Large Inverter Motors

TFL 6336M/C4VL2071 can be considered for bearing positions in large inverter motors, including industrial motor series such as ABB M3BP and Siemens 1LE0001.

During long-term operation of large VFD motors, shaft voltage may generate circulating currents through the bearing, causing electrical erosion at rolling contact areas. For motors operating with higher temperature rise and thermal expansion, the C4 clearance of 6336M/C4VL2071 provides additional operating clearance, while the VL2071 inner-ring ceramic insulation helps isolate shaft-side current paths.

inner ring insulated deep groove ball bearing for industrial generator

Industrial Generator Bearing

TFL 6336M/C4VL2071 can be considered for bearing positions in large industrial generators and synchronous generator systems, including equipment types such as ABB industrial generators and Siemens Gamesa power generation systems.

During generator operation, magnetic field changes and rotor systems may generate shaft voltage, allowing the bearing to become a leakage path for electrical current. Compared with standard bearings, electrically insulated bearings help reduce the risk of current passing through rolling contact areas. The VL2071 inner-ring insulation of 6336M/C4VL2071 is suitable for generator applications requiring shaft-side electrical isolation and increased internal clearance.

inner ring ceramic coating bearing for mining ball mills

High-Temperature Industrial Drive Systems

TFL 6336M/C4VL2071 can be considered for high-temperature continuous-duty industrial drive systems, including metallurgy equipment, heavy machinery drive units, and large production line motor systems.

These applications often operate for extended periods and may experience temperature rise, thermal expansion, and electrical interference caused by variable-frequency control. The C4 clearance of 6336M/C4VL2071 supports applications requiring increased internal clearance, while the VL2071 inner-ring insulation helps reduce bearing damage risks caused by shaft currents.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Can 6336M/C4VL2071 be used as a generator bearing?

It can be considered as an electrically insulated bearing candidate for industrial generators and large electric drive systems, especially where inner-ring insulation and C4 clearance are required. Final selection should confirm the generator design and original bearing designation.

Does 6336M/C4VL2071 have outer-ring or inner-ring insulation?

6336M/C4VL2071 uses VL2071 inner-ring insulation, with the insulation coating applied to the bearing inner ring. It differs from VL0241 outer-ring insulated models, and the required insulation location should be confirmed before replacement.

What information is needed before purchasing 6336M/C4VL2071?

Buyers should provide the complete designation, original brand model, equipment type, mounting position, quantity, operating temperature, and delivery requirement. For SKF or FAG replacement, old bearing photos and nameplate information are also recommended.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.