6336M/C3VL0241 Electrically Insulated Ball Bearings

6336M/C3VL0241 Electrically Insulated Ball Bearings

Motor Repair Replacement 6336M/C3VL0241 - Get Your Wholesale Quote Now

$ 750 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6336M/C3VL0241
  • Equivalent Interchange 6336M/C3VL0241 (SKF); 6336-M-J20AA-C3 (FAG);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL0241
  • Insulating Coating Types Insulation coating on outer ring
  • Manufacturers TFL
  • Bore Diameter 180.0 mm
  • Outside Diameter 380.0 mm
  • Width 75.0 mm
  • Net Weight 42.4 kg
  • Basic Dynamic Load Rating 355.0 kN
  • Basic Static Load Rating 405.0 kN
  • Reference Speed 3000 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6336M/C3VL0241 Equivalent Interchange Brands

TFL 6336M/C3VL0241 has an interchange basis with SKF, FAG, and other insulated bearing types through its dimensions, C3 clearance, and VL0241 outer-ring insulation structure. VL0241 outer-ring insulation is mainly used in large motors and industrial drive applications where isolation of the housing-side current path is required.

Replacement should not be determined only from the base designation 6336M. Buyers should verify the complete suffix, clearance class, cage type, insulation location, and operating conditions. TFL can assist with SKF/FAG interchange list and direct replacement review based on the original bearing designation, photos, and application information.

SKF FAG
6336M/C3VL0241 6336-M-J20AA-C3

Why Choose TFL?

TFL focuses on electrically insulated bearing supply, providing model verification, interchange review, and delivery support for industrial buyers, motor repair teams, and distributors. For large VL0241 outer-ring insulated bearings, we verify dimensions, C3 clearance, insulation location, cage type, and complete original designations.

TFL supports No MOQ, small maintenance orders, bulk purchasing, OEM/ODM, and consolidated shipments, helping customers meet insulation requirements while reducing sourcing costs.

Features of 6336M/C3VL0241

Common Applications of Electrically Insulated Bearings

TFL 6336M/C3VL0241 electrically insulated deep groove ball bearing is suitable for large inverter motors, industrial generators, large compressors, and other electric drive systems where shaft current protection is required.

The VL0241 outer-ring insulation structure helps isolate housing-side current paths and reduce electrical erosion risks. The C3 clearance and brass cage support continuous operation, temperature variation, and long-term load conditions.

Final selection should be verified by original dimensions, insulation location, clearance, fits, load, and speed.

Image of electrically insulated bearing installed in an electric motor assembly

Large Inverter Motors

TFL 6336M/C3VL0241 can be considered for large inverter motor equipment types, including Siemens 1LE0001 and ABB M3BP series.

Inverter-driven operation may generate shaft currents, allowing the bearing to become part of the current path and causing electrical erosion. The VL0241 outer-ring alumina ceramic insulation helps interrupt housing-side current paths and is suitable for replacement review where outer-ring insulation and C3 clearance are specified.

Industrial Generators

TFL 6336M/C3VL0241 can be considered for bearing positions in industrial generators and large synchronous generators, including equipment types from ABB generators and Siemens Gamesa wind generators.

Generator operation may create shaft voltage and circulating currents due to magnetic field variations. The VL0241 outer-ring insulation bearing can be considered as a candidate solution during generator bearing replacement review.

Photo showing insulated bearing in a water pump mechanism

Large Compressor Systems

TFL 6336M/C3VL0241 can be considered for bearing positions in large industrial compressor and motor drive systems.

Centrifugal compressors often operate continuously under variable-frequency control, high loads, and complex grounding conditions where shaft current issues may occur. The outer-ring insulation structure helps reduce bearing damage risks caused by electrical current and can be considered for insulated bearing replacement in compressor drive systems.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

What type of insulated bearing is 6336M/C3VL0241?

6336M/C3VL0241 is a VL0241 outer-ring insulated deep groove ball bearing, with the ceramic insulation coating applied to the outer ring to isolate housing-side current paths.

Can 6336M/C3VL0241 be used as a generator bearing?

It can be considered as an electrically insulated bearing candidate for industrial generators and large electric drive systems, but the original equipment should be confirmed to require outer-ring insulation and the dimensions, clearance, and mounting conditions should be verified.

Is 6336M/C3VL0241 available for small quantity purchasing?

Yes. TFL supports No MOQ, small maintenance orders, replacement stock requirements, and bulk supply.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.