6334M/C3VL0241 Electrically Insulated Ball Bearings

6334M/C3VL0241 Electrically Insulated Ball Bearings

Insocoat Bearing 6334M/C3VL0241 - Economical Replacement

$ 686 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6334M/C3VL0241
  • Equivalent Interchange 6334M/C3VL0241 (SKF); 6334-M-J20AA-C3 (FAG);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL0241
  • Insulating Coating Types Insulation coating on outer ring
  • Manufacturers TFL
  • Bore Diameter 170.0 mm
  • Outside Diameter 360.0 mm
  • Width 72.0 mm
  • Net Weight 36.7 kg
  • Basic Dynamic Load Rating 325.0 kN
  • Basic Static Load Rating 365.0 kN
  • Reference Speed 3200 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6334M/C3VL0241 Equivalent Interchange Brands

TFL 6334M/C3VL0241 has an interchange basis with corresponding SKF and FAG models through its 170 × 360 × 72 mm boundary dimensions, C3 clearance, and outer-ring insulation structure. It can be reviewed through an INSOCOAT equivalent chart or SKF/FAG interchange list. VL0241 and J20AA generally indicate outer-ring insulated types, so buyers should not judge replacement only from the base designation 6334M. TFL can review dimensions, clearance, cage type, and insulation location from the original bearing photo, complete model number, equipment type, and mounting position. Final direct replacement should be verified against fit arrangement, speed, load, temperature rise, lubrication method, and original machine requirements.

SKF FAG
6334M/C3VL0241 6334-M-J20AA-C3

Why Choose TFL?

TFL supports industrial buyers, motor repair teams, and distributors with insulated bearing model consolidation, interchange confirmation, and pre-shipment checking. For large outer-ring insulated bearings such as 6334M/C3VL0241, we focus on the 170 × 360 × 72 mm dimensions, C3 clearance, VL0241 insulation location, brass cage, and original brand suffix to reduce selection errors in replacement purchasing. TFL supports No MOQ, small maintenance orders, volume purchasing, OEM/ODM, and consolidated shipment of multiple bearing models for large motor repair, wind service, project sourcing, and alternative-brand supply. The listed ROHS and REACH status is Compliant; specific document requirements can be confirmed at the RFQ or order stage.

insocoat deep groove ball bearing 6334M/C3VL0241

Features of 6334M/C3VL0241

Common Applications of Electrically Insulated Bearings

TFL 6334M/C3VL0241 electrically insulated deep groove ball bearing is suitable for large inverter motors, industrial motors, wind turbine generators, industrial pump motors, compressor motors, and heavy-duty drive systems. Its VL0241 outer-ring insulation helps interrupt current paths between the housing and bearing outer ring, reducing electrical erosion and fluting risk under inverter-driven or generator operation. The 325 kN dynamic load rating, 365 kN static load rating, C3 clearance, and brass cage fit continuous-duty and higher-load conditions in large motor bearing positions. Final application should be checked against the original bearing suffix, insulation location, fits, temperature rise, load, and speed.

The picture shows the Electrically Insulated Bearings used in modern motors.

Large Inverter Motors

TFL electrically insulated deep groove ball bearings, such as 6334M/C3VL0241 and 6334M/C4VL0241, can be considered for large inverter motor equipment types, including Siemens 1LE0001 and ABB M3BP series. In these motors, inverter-driven operation may generate shaft currents and cause electrical erosion or fluting on bearing raceways. The VL0241 outer-ring alumina ceramic insulation of 6334M/C3VL0241 provides 1000–3000 V DC dielectric protection, making it a replacement candidate for SKF INSOCOAT VL0241 and FAG J20AA types where outer-ring insulation and C3 clearance are specified. This is an application-type reference, not an installed case.

Illustration of insulated bearing within a wind turbine generator

Wind Turbine Generators

TFL electrically insulated bearings, such as 6334M/C3VL0241, can be considered for generator bearing positions in wind turbine generators exposed to shaft current, electrical erosion, or high-humidity operating conditions, including equipment types such as Vestas V90, Goldwind GW121/2500, and Siemens Gamesa 2.3 MW turbines. Wind turbine generators operate under variable speed, vibration, humidity, and fluctuating load conditions, so insulation location, clearance class, and cage structure should be checked carefully. With VL0241 outer-ring insulation, C3 clearance, and a brass cage, 6334M/C3VL0241 is a candidate for wind turbine generator bearing replacement review. This is an application-type reference, not an installed case.

anti-current insulated bearing for railway traction

Rail Traction Motors

TFL electrically insulated bearings, such as 6334M/C3VL0241, can be considered for bearing positions in rail traction motors exposed to shaft current, electrical erosion, or inverter-drive effects. Traction motors usually operate under high load, frequent start-stop conditions, vibration, and variable speed, so bearing selection should verify dimensions, clearance, insulation location, cage structure, and original equipment requirements. With VL0241 outer-ring insulation, C3 clearance, and a brass cage, 6334M/C3VL0241 is a candidate for traction motor bearing replacement review. This is an application-type reference, not an installed case.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Why should packaging and shipping method be confirmed when purchasing 6334M/C3VL0241?

6334M/C3VL0241 has a net weight of about 36.7 kg and is a large-size electrically insulated bearing. Buyers should confirm single-piece packaging, moisture protection, label information, outer-carton method, and whether pallet shipping is required. If the same order includes multiple models, model-by-model labeling and consolidated shipment requirements can also be stated in advance.

Is 6334M/C3VL0241 suitable for wind turbine generator bearing replacement?

It can be considered as a candidate for wind turbine generator bearing replacement, especially where the original machine requires 170 × 360 × 72 mm dimensions, C3 clearance, VL0241 outer-ring insulation, and a brass cage. Wind turbine applications should also check humidity, vibration, temperature rise, load fluctuation, and original machine requirements instead of replacing by base designation alone.

How can stock status and lead time for 6334M/C3VL0241 be confirmed?

Stock status and lead time depend on inventory at the time of inquiry, quantity, packaging requirements, destination country or region, and shipping method. Buyers should provide the model 6334M/C3VL0241, required quantity, target arrival date, and whether partial shipment is acceptable. For shutdown maintenance orders, equipment status can also be provided to help prioritize delivery planning.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.