6338M/C3VL2071 Electrically Insulated Ball Bearings

6338M/C3VL2071 Electrically Insulated Ball Bearings

Cost-Effective SKF Alternative 6338M/C3VL2071 - Fast Sourcing Option

$ 814 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6338M/C3VL2071
  • Equivalent Interchange 6338M/C3VL2071 (SKF); 6338-M-J20C-C3 (FAG);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL2071
  • Insulating Coating Types Inner ring insulation coating
  • Manufacturers TFL
  • Bore Diameter 190.0 mm
  • Outside Diameter 400.0 mm
  • Width 78.0 mm
  • Net Weight 49.1 kg
  • Basic Dynamic Load Rating 380.0 kN
  • Basic Static Load Rating 455.0 kN
  • Reference Speed 2850 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C3
  • ROHS Compliant
  • REACH Compliant

6338M/C3VL2071 Equivalent Interchange Brands

TFL 6338M/C3VL2071 has an interchange basis with SKF, FAG, and other insulated bearing types through its dimensions, C3 clearance, and VL2071 inner-ring insulation structure. VL2071 indicates an inner-ring insulation design mainly used for large motor and generator systems requiring shaft-side current isolation.

Replacement should not be determined only by the base designation 6338M. The complete suffix, insulation location, clearance class, cage type, and operating conditions should also be verified. TFL provides SKF/FAG interchange review and direct replacement support based on original bearing information, equipment details, and installation requirements.

SKF FAG
6338M/C3VL2071 6338-M-J20C-C3

Why Choose TFL?

TFL specializes in electrically insulated bearing supply, providing model verification, interchange review, and delivery support for industrial buyers, maintenance teams, and distributors. For large VL2071 inner-ring insulated bearings such as 6338M/C3VL2071, we verify bearing dimensions, C3 clearance, insulation location, cage type, and original designations to reduce replacement risks.

TFL supports No MOQ, small maintenance orders, bulk purchasing, OEM/ODM, and consolidated supply programs, helping customers meet insulation requirements while optimizing sourcing costs.

inner ring coating insulated deep groove ball bearing 6338M/C3VL2071

Features of 6338M/C3VL2071

Common Applications of Electrically Insulated Bearings

TFL 6338M/C3VL2071 electrically insulated deep groove ball bearing is suitable for large inverter motors, industrial generators, heavy-duty industrial drive systems, and other equipment where shaft current protection is required.

As a large-size deep groove ball bearing, 6338M/C3VL2071 is mainly used in electric drive equipment requiring stable operation, continuous service capability, and reliable insulation protection. The VL2071 inner-ring insulation structure helps isolate shaft-side current paths and reduce electrical erosion risks caused by shaft currents. The C3 clearance supports temperature rise and thermal expansion conditions in large equipment. Final selection should be verified according to dimensions, mounting conditions, load, speed, and original bearing specifications.

Massive electric drive motor for a mine hoist system requiring heavy-duty insulated 6238M bearings.

Large Inverter Motors

TFL 6338M/C3VL2071 can be considered for bearing positions in large inverter motors, including industrial motor equipment types such as ABB M3BP and Siemens 1LE0001 series.

As motor power and frame size increase, inverter-generated high-frequency voltage can create shaft currents more easily. When current passes through the rolling contact area of standard bearings, it may cause electrical erosion, raceway damage, and lubricant deterioration.

The VL2071 inner-ring alumina ceramic helps isolate shaft-side current paths. Meanwhile, the C3 clearance and brass cage configuration support continuous operation in large motor applications.

inner ring insulated deep groove ball bearing for industrial generator

Industrial Generator Bearing

TFL 6338M/C3VL2071 can be considered for bearing positions in large industrial generators and synchronous generator systems, including equipment types such as ABB generators and Siemens Gamesa generator systems.

During generator operation, rotor magnetic field changes, grounding conditions, and electrical imbalance may generate shaft voltage, causing the bearing to become a current leakage path. For large power generation equipment, bearing insulation is an important consideration for reducing electrical erosion risks.

The VL2071 inner-ring insulation of 6338M/C3VL2071 helps isolate shaft-side currents, while the C3 clearance supports the operating requirements of large generators under continuous service conditions.

Inner ring coated bearing preventing electrical erosion for wind turbines

Heavy-Duty Industrial Drive Equipment

TFL 6338M/C3VL2071 can be considered for bearing positions in heavy-duty industrial drive equipment, including steel processing equipment, mining machinery drive systems, large fan drive units, and other continuous-duty electric drive applications.

These systems typically operate with higher motor power and longer service periods. Bearings must handle continuous mechanical loads while also dealing with electrical effects caused by inverter-controlled operation.

With its large-size deep groove ball bearing design, brass cage, and VL2071 inner-ring insulation configuration, this bearing helps reduce bearing damage risks caused by shaft currents while maintaining standard replacement capability.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

What is the difference between 6338M/C3VL2071 and a standard 6338M bearing?

The main difference is the insulation design. 6338M/C3VL2071 features a VL2071 alumina ceramic insulation coating on the inner ring to isolate shaft-side current paths, while a standard 6338M bearing does not provide electrical insulation.

Can VL2071 and VL0241 versions be exchanged directly?

They should not be exchanged only based on the base designation. 6338M/C3VL2071 provides inner-ring insulation, while VL0241 provides outer-ring insulation. The required insulation location should be confirmed before replacement.

What information should be provided when purchasing 6338M/C3VL2071?

Buyers should provide the complete designation, original brand model, equipment type, mounting position, quantity, operating conditions, and delivery requirements. For SKF or FAG replacement, old bearing photos or equipment nameplate information are also recommended.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.