6338M/C4VL2071 Electrically Insulated Ball Bearings

6338M/C4VL2071 Electrically Insulated Ball Bearings

Affordable Replacement for SKF 6338M/C4VL2071 - Your Reliable B2B Supplier

$ 814 /Each
  • Customized Logo: Min. Order 1 Piece
  • Customized Packaging: Min. Order 1 Piece
  • Inventory: In stock
  • Country of Origin: China
Popular

Product Parameters

  • Model 6338M/C4VL2071
  • Equivalent Interchange 6338M/C4VL2071 (SKF); 6338-M-J20C-C4 (FAG);
  • Product Category Electrically Insulated Ball Bearings
  • Coating Suffix VL2071
  • Insulating Coating Types Inner ring insulation coating
  • Manufacturers TFL
  • Bore Diameter 190.0 mm
  • Outside Diameter 400.0 mm
  • Width 78.0 mm
  • Net Weight 49.1 kg
  • Basic Dynamic Load Rating 380.0 kN
  • Basic Static Load Rating 455.0 kN
  • Reference Speed 2850 r/min
  • Breakdown Voltage (DC) 1000 ~3000 V
  • Layer Thickness 100~500 µm
  • Electrical Resistance 50~200 MΩ
  • Cage Material Brass cage
  • Radial Internal Clearance C4
  • ROHS Compliant
  • REACH Compliant

6338M/C4VL2071 Equivalent Interchange Brands

TFL 6338M/C4VL2071 has an interchange basis with SKF, FAG, and other insulated bearing types through its dimensions, C4 clearance, and VL2071 inner-ring insulation structure. VL2071 indicates an inner-ring insulation design for large motor and generator systems requiring shaft-side current isolation.

Compared with C3 clearance versions, C4 clearance is mainly selected for higher operating temperatures, greater thermal expansion, or applications requiring increased internal clearance. Replacement should verify the complete designation, insulation location, clearance class, and operating conditions.

SKF FAG
6338M/C4VL2071 6338-M-J20C-C4

Why Choose TFL?

TFL focuses on electrically insulated bearing supply, providing model verification, interchange review, and delivery support for industrial buyers, motor repair teams, and distributors. For large VL2071 inner-ring insulated bearings such as 6338M/C4VL2071, we verify dimensions, C4 clearance, insulation location, cage type, and complete original designations to reduce selection errors.

TFL supports No MOQ, small maintenance orders, bulk purchasing, OEM/ODM, and consolidated shipments, helping customers meet high-temperature operation and electrical insulation requirements while reducing sourcing costs.

skf insocoat bearing alternative deep groove ball bearing 6338M/C4VL2071

Features of 6338M/C4VL2071

Common Applications of Electrically Insulated Bearings

TFL 6338M/C4VL2071 electrically insulated deep groove ball bearing is suitable for large inverter motors, industrial generators, high-temperature continuous-duty electric drive systems, and other equipment where shaft current protection is required.

The VL2071 inner-ring insulation structure helps isolate shaft-side current paths and reduce electrical erosion risks. C4 clearance is suitable for large equipment with higher operating temperatures, greater thermal expansion, or increased internal clearance requirements.

Final selection should be verified by original dimensions, insulation location, clearance, fits, load, and speed.

image shows two type insulated ball bearing and an industrial dc motor. One of the bearing is with machined brtass cage, another insulated bearing is with stamped steel cage.

Large Inverter Motors

TFL 6338M/C4VL2071 can be considered for bearing positions in large inverter motors, including industrial motor equipment types such as ABB M3BP and Siemens 1LE0001 series.

As motor power ratings increase, inverter-driven systems can generate higher-frequency voltage that may create shaft currents. When current passes through standard bearing rolling contacts, electrical erosion, raceway damage, and lubricant deterioration may occur.

The VL2071 inner-ring ceramic insulation of 6338M/C4VL2071 helps isolate shaft-side current paths. The C4 clearance and brass cage combination support continuous operation in large motor applications.

inner ring insulated deep groove ball bearing for industrial generator

Industrial Generator Bearing

TFL 6338M/C4VL2071 can be considered for bearing positions in large industrial generators and synchronous generator systems, including equipment types such as ABB generators and Siemens Gamesa generation systems.

During generator operation, rotor magnetic field changes, electrical imbalance, and grounding conditions may generate shaft voltage, allowing the bearing to become a current leakage path. For large power generation equipment, reducing shaft current-related bearing damage is an important reliability consideration.

The VL2071 inner-ring insulation structure of 6338M/C4VL2071 helps isolate shaft-side currents, while the C4 clearance supports internal clearance requirements during long-term operation.

The image shows one insulated bearing with brass retainer and inner ring coating, one insulated bearing with sheet mental and inner ring coating, two bearing both for wind turbine system.

Heavy-Duty Industrial Drive Systems

TFL 6338M/C4VL2071 can be considered for large industrial drive equipment, including steel production machinery, mining equipment, motor-driven fans, and large production line transmission systems.

These applications typically involve high motor power and long operating periods. Bearings must handle continuous mechanical loads while also dealing with electrical effects from inverter-controlled operation.

With its large bearing structure, brass cage, and VL2071 inner-ring insulation design, 6338M/C4VL2071 helps reduce shaft current-related bearing damage risks while supporting stable operation in industrial equipment.

*The brands and series mentioned are provided for industry illustration only. Final bearing selection should be confirmed through verification of dimensions, clearance class, insulation type, and operating conditions. For selection assistance or technical consultation, please contact the TFL engineering team for support.

Q&A

Why do large motors use C4 clearance bearings?

Large motors experience temperature rise and thermal expansion during operation. C4 clearance provides additional internal space to avoid insufficient operating clearance. However, C4 selection must match the equipment design requirement.

Can 6338M/C4VL2071 be used as a generator bearing?

It can be considered as an electrically insulated bearing candidate for industrial generators and large electric drive systems, especially where inner-ring insulation and C4 clearance are required. Final selection should confirm the generator design and original bearing designation.

What is the difference between 6338M/C4VL2071 and a standard 6338M bearing?

6338M/C4VL2071 adds a VL2071 alumina ceramic insulation coating on the inner ring to isolate shaft-side current paths, while a standard 6338M bearing does not provide electrical insulation. The basic dimensions may be the same, but the intended application is different.
Send Inquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Need a Reliable Technical Solution?

We're more than a supplier; we're a manufacturing partner with 20+ years of R&D experience. Speak with our engineers, and you'll find our expertise can solve your electrical erosion issues and significantly reduce long-term maintenance costs.

Get a Free Custom Solution & Quote

弹窗表单

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 2 GB.